DIN1.FILTER TO DIN7.FILTER

Description

This parameter sets the digital input filter configuration for channel x when followed with the values defined below. DINx.FILTER retrieves this information when not followed by data.

Value

Description

DINX.FILTER 0

The drive digital input channel detects all input signals with an input pulse width of ≥ 40 ns (no filtering applied).

DINX.FILTER 1

The drive digital input channel detects all input signals with an input pulse width of ≥ 10.24 µs, ± 0.64 µs (fast filter applied).

DINX.FILTER 2

The drive digital input channel detects all input signals with an input pulse width of ≥ 163 µs, ± 10.24 µs (standard filter applied).

DINX.FILTER 3

The drive digital input channel detects all input signals with an input pulse width of ≥ 2.62 ms, ± 0.16384 ms (slow filter applied).


  • AKD-N only supports DIN1 to DIN3.

General Information

Type

R/W Parameter

Units

N/A

Range

0 to 3

Default Value

1 for DIN1 and DIN2

2 for DIN3 to DIN7

Data Type

Integer

Start Version

M_01-03-07-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD Profinet Yes
AKD sercos® III Yes
AKD-N Yes
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

Fieldbus Index/Subindex Object Start Version

EtherCAT COE and CANopen

51CBh /0 DIN1.FILTER M_01-03-07-000
51CCh /0 DIN2.FILTER
51CDh /0 DIN3.FILTER
51CEh /0 DIN4.FILTER
51CFh /0 DIN5.FILTER
51D0h /0 DIN6.FILTER
51D1h /0 DIN7.FILTER
Parameter

Fieldbus

Address

Attributes Signed?
DIN1.FILTER

Profinet

2459 Word No
sercos® III 2 Octets
DIN2.FILTER

Profinet

2460 Word
sercos® III 2 Octets
DIN3.FILTER

Profinet

2461 Word
sercos® III 2 Octets
DIN4.FILTER

Profinet

2462 Word
sercos® III 2 Octets
DIN5.FILTER

Profinet

2463 Word
sercos® III 2 Octets
DIN6.FILTER

Profinet

2464 Word
sercos® III 2 Octets
DIN7.FILTER

Profinet

2465 Word
sercos® III 2 Octets
Fieldbus Parameter Instance Data Size Data Type
EtherNet/IP DIN1.FILTER 460 2 Byte Integer
DIN2.FILTER 461
DIN3.FILTER 462
DIN4.FILTER 463
DIN5.FILTER 464
DIN6.FILTER 465
DIN7.FILTER 466

Fieldbus

Index/Subindex

Is 64 bit? Attributes Signed?
Modbus 918 DIN1.FILTER No 16 bit No
920 DIN2.FILTER
922 DIN3.FILTER
924 DIN4.FILTER
926 DIN5.FILTER
928 DIN6.FILTER
930 DIN7.FILTER

Related Topics

Digitale Eingänge und Ausgänge